Feature:
- The respirator is also suitable for use with Ayre's Tee resuscitation circuit, high-frequency positive pressure breathing using a bronchoscope injector, and in a closed-circuit system that includes a carbon dioxide absorber.
- The time-cycled Penlon Nuffield 200 is powered by medical air or oxygen at 340 KPA – 410 KPA and has a predetermined volume and flow rate for small and large animals.
- You can replace the standard patient valve with a Newton Valve and the scope of the ventilator has been expanded to include ventilation of small animals – a great achievement for a small inexpensive ventilator. A great achievement for a small inexpensive ventilator.
- The Nuffield 200 is a compressed air ventilator with a predetermined volume and flow rate for adult or pediatric patients.
- The four simple controls offer a wide range of settings that allow a steady flow during the inhalation phase and the endless variety of I: E settings.
- A suitable alarm device for the ventilator and a pollution control system can be attached to the ventilator if necessary.
- The Penlon Series 200 requires higher engine pressure to operate.
- It will not work with O2 capacitor due to low pressure output.
- Compact and easy to use
- Versatile capabilities, including coaxial coaxial circuit, Ayre's Tee circuit, circuit and recovery system
- Comes with a valve for children and adults
- Standard Schrader oxygen hose probe installation
- Compatible with magnetic resonance imaging (optional)
- The main unit and valves can be sold separately
Specification
Dimensions | 270 × 210 × 100 mm |
Weight | 3.5 kg |
Drive Gas | Medical air or oxygen at 340 KPA (50 pounds of force / in2) – 410 KPA (60 pounds of force / in2) |
Tidal Volume | 10ml – 300ml (Newton valve) " 50ml – 2000ml (standard valve) |
Frequency (Cycle/Min) | 10-85 (rpm / min) |
Frequency For HFPPV | HFPPV (r / min) |
Inspiratory Flow (Liters Per Sec) | 0.25 – 1.0 (independent and constantly changing) |
I: E Ratio | Constantly variable and depends on the selected I: E settings |
Gas consumption | Min volume plus 0.1 L / cycle for operation of a fluid logic circuit |
Minute Volume | 1.0-30.0 liters |
Inspiratory | Time: 0.2-2.0 seconds. (Independent and continuously variable) "flow: 0.25 – 1.0 L / s( independent and continuously variable)" pressure relief: 60 cm H2O |
Expiratory | Time: 0.5 – 4.0 seconds. (Independent and continuously variable) resistance: 2.5 cm water / L |
Respiratory Manometer | The range is from -20 to +100 cm 2o hour with the possibility of setting zero |